Cold aisle containment solutions increase your cooling efficiency whilst reducing power consumption.
Cold aisle containment is a method of increasing cooling efficiency, reducing power consumption and is intended to prevent air temperature zones from being mixed together in a data centre.
Cold air is fed through a false floor into a contained cold aisle. This air flows through the front of the server racks, removes the heat from installed equipment and is expelled as hot air through the rear of the cabinet. The hot air is then removed by the data centre air conditioning system.
Having the cold aisle contained means the area requiring cooling is much smaller and therefore less power is required by the C.R.A.C (computer room air conditioner) unit to keep it at the recommended temperature.
Cold aisle containment ensures businesses do not have to increase the cooling capacity within the data centre whilst increasing cooling efficiency and reducing costs.
Features
The main benefits of cold aisle containment are:
Avoids hot air short circuits
Reduces the volume of air that needs to be cooled
Improves efficiency of the cooling system considerably
Energy cost savings
Installing a cold aisle in a workplace improves the working environment for staff, as the room does not need to be kept at a low ambient temperature. Even the cold aisle can often be warmer than that of an uncontained data centre. An uncontained data centre needs to have it’s air conditioning set for the installation that requires the most cooling, where ever that is within the data centre.
B&R Enclosures cold aisle containment systems are quoted on a project basis after an on-site consultation with one of our experienced sales engineers.
Climate control accessories such as spare filters to prevent dust entering the enclosure, thermostats, humidistats, level switch and solenoid valves.
Applications
Most of the Climate Control product range requires the use of a filter to prevent dust entering the enclosure. Many of these can be controlled for best effect by a thermostat, humidistat, level switch or solenoid valve. These products are also available from B&R. However for the complete list, please contact us and let us know the model number of the product you are interested in.
An energy saving, 40W local visual caution lights manufactured from copper-free aluminium alloy and suitable for hazardous area locations.
Applications
The explosion proof, ex d rated, 40W caution lights are an energy saving light designed for use in chemical, petrochemical, grain, dust and other hazardous area applications.
Features
Low power consumption and long service life up to 30,000 hours
Flash frequency – 20-60 times per minute
Maximum luminous intensity >2000cd
Technical Information
Protection Ratings Ex d e IIC T6 Gb Ex tb IIIC T80ºC Db IP66